38kV Outdoor Automatic Recloser
auto-recloser

38kV Outdoor Automatic Recloser

The 38kV outdoor automatic recloser serves 33kV three-phase overhead distribution lines (50/60Hz), compliant with IEC 62271-111 and IEEE C37.60. The highest voltage class in the NAIJI recloser series, completing the 15.5kV / 27kV / 38kV sequence for global 11kV, 24kV, and 33kV grid coverage. Available in three-phase ganged or independent mechanism configurations. Significantly upgraded insulation distances, creepage distances, and vacuum interrupter sizing. 304/316 stainless steel enclosure with outdoor corrosion protection.

Caracteristicas Principales

  • 38kV rated voltage, 630A rated current
  • Power-frequency withstand: 70kV; Lightning impulse: 170kV
  • 10,000 mechanical operations life
  • Closing time: ≤60ms; Opening time: ≤45ms
  • Partial discharge: ≤20pC at 1.1Ur/√3
  • Built-in CT: 600A/1A, accuracy class 0.5S
  • Highest voltage class — completes 15.5/27/38kV series
  • Significantly upgraded insulation and creepage distances
  • 304/316 stainless steel enclosure
  • IEC 62271-111 & IEEE C37.60 compliant

Especificaciones Tecnicas

Rated Voltage38kV
Rated Current630A
Power-Frequency Withstand (Phase/Earth & Across Gap)70kV
Lightning Impulse Withstand (Peak)170kV
Mechanical Life10,000 operations
Contact Gap15±1mm
Closing Time≤60ms
Opening Time≤45ms
Partial Discharge≤20pC
Built-in CT Ratio600A/1A
CT Accuracy Class0.5S (5P10)
Operating Temperature-40°C to +45°C
Frequency50/60Hz
Enclosure Material304/316 Stainless Steel
StandardsIEC 62271-111, IEEE C37.60

Aplicaciones

33kV overhead distribution linesSub-transmission distribution networksDistribution automation (DA/FA)Fault isolation and auto-reclosing

Cumplimiento de Normas

IEC 62271-111IEEE C37.60
Respuesta en 12hCertificado ISO / CE / CCCOEM Disponible

Preguntas Frecuentes

Cual es la tension nominal del 38kV Outdoor Automatic Recloser?
El 38kV Outdoor Automatic Recloser tiene una tension nominal de 38kV. Consulte la tabla de especificaciones tecnicas para las clasificaciones electricas completas.
Cual es el plazo de entrega para el 38kV Outdoor Automatic Recloser?
El plazo de entrega estandar para el 38kV Outdoor Automatic Recloser es de aproximadamente 30 dias. Cantidades mayores o configuraciones personalizadas pueden requerir tiempo de produccion adicional.
Se puede personalizar el 38kV Outdoor Automatic Recloser para proyectos OEM?
Si, NAIJI Electric ofrece fabricacion OEM y personalizada para el 38kV Outdoor Automatic Recloser. Podemos ajustar especificaciones, marca y configuraciones segun requisitos especificos del proyecto.
Que normas cumple el 38kV Outdoor Automatic Recloser?
El 38kV Outdoor Automatic Recloser esta disenado y probado de acuerdo con IEC 62271-111, IEEE C37.60. Todos los productos se someten a pruebas rigurosas de fabrica antes del envio.

Interesado en 38kV Outdoor Automatic Recloser?

Obtenga precios directos de fabrica, especificaciones tecnicas y opciones de configuracion personalizada.