The SPV-24 is a 24kV oil-free, SF6-free, maintenance-free outdoor vacuum circuit breaker by NAIJI Electric. Extended voltage class with enhanced insulation levels (125/145kV lightning impulse withstand). Same proven longitudinal magnetic field rotating arc technology and solid epoxy resin insulation (APG vacuum casting) as the SPV-12. Every unit X-ray inspected. Weighs only 2/3 of comparable products. Ideal for 20kV distribution systems and higher voltage applications.

Caracteristicas Principales

  • 24kV rated voltage — higher insulation class, oil-free, SF6-free
  • Enhanced lightning impulse withstand: 125/145kV
  • Longitudinal magnetic field rotating arc — same proven technology as SPV-12
  • Solid epoxy resin insulation (APG vacuum cast) — 20+ years outdoor proven
  • Every unit 100% X-ray inspected
  • Mechanical life: 10,000 operations
  • Electrical life: 10,000+ operations at rated current
  • Only 2/3 weight of comparable products
  • Imported spring wire + bearing structure + zinc-nickel-cobalt alloy treatment
  • Compatible with FTU for 20kV distribution automation

Especificaciones Tecnicas

Rated Voltage24 kV
Rated Current630 / 1250 A
Rated Frequency50 Hz
Rated Short-Circuit Breaking Current20 / 25 kA
Rated Peak Withstand Current50 / 63 kA
Rated Short-Circuit Making Current (peak)50 / 63 kA
Rated Short-Time Withstand Current20kA/4s, 25kA/4s
Rated Operating SequenceO—0.3s—CO—180s—CO
Short-Circuit Breaking Operations20 times
Lightning Impulse Withstand (phase-phase/earth)125 kV (peak)
Lightning Impulse Withstand (across isolating distance)145 kV (peak)
Power Frequency Withstand 1min Dry (phase/earth · across gap)65 / 79 kV
Power Frequency Withstand 1min Wet (phase/earth · across gap)50 / 64 kV
Secondary Circuit Withstand Voltage2000 V
Contact Distance12±1 mm
Contact Overtravel3.5±1 mm
Opening Speed1.4±0.2 m/s
Closing Speed0.7±0.2 m/s
Contact Closing Bounce Time≤2 ms
Phase-to-Phase Distance380±1.5 mm
Three-Phase Synchronization≤2 ms
Circuit Resistance (per phase)≤70 μΩ
Closing Time25~60 ms
Opening Time20~40 ms
Energy Storage Motor Power40 W
Mechanical Life10,000 operations
Electrical Life10,000+ operations
Insulation MediumSolid epoxy resin (APG vacuum cast)
Arc ExtinguishingLongitudinal magnetic field rotating arc
Temperature Range-25°C to +40°C
Weight2/3 of comparable products
MaintenanceMaintenance-free

Aplicaciones

20kV distribution network switchingHigh-voltage substationsIndustrial power supply systemsRenewable energy grid connectionsRing network sectionalizing (20kV systems)Distribution automation with FTU

Cumplimiento de Normas

IEC 62271-100GB 1984
Respuesta en 12hCertificado ISO / CE / CCCOEM Disponible

Preguntas Frecuentes

Cual es la tension nominal del SPV-24 Outdoor Vacuum Circuit Breaker (24kV)?
El SPV-24 Outdoor Vacuum Circuit Breaker (24kV) tiene una tension nominal de 24 kV. Consulte la tabla de especificaciones tecnicas para las clasificaciones electricas completas.
Cual es el plazo de entrega para el SPV-24 Outdoor Vacuum Circuit Breaker (24kV)?
El plazo de entrega estandar para el SPV-24 Outdoor Vacuum Circuit Breaker (24kV) es de aproximadamente 30 dias. Cantidades mayores o configuraciones personalizadas pueden requerir tiempo de produccion adicional.
Se puede personalizar el SPV-24 Outdoor Vacuum Circuit Breaker (24kV) para proyectos OEM?
Si, NAIJI Electric ofrece fabricacion OEM y personalizada para el SPV-24 Outdoor Vacuum Circuit Breaker (24kV). Podemos ajustar especificaciones, marca y configuraciones segun requisitos especificos del proyecto.
Que normas cumple el SPV-24 Outdoor Vacuum Circuit Breaker (24kV)?
El SPV-24 Outdoor Vacuum Circuit Breaker (24kV) esta disenado y probado de acuerdo con IEC 62271-100, GB 1984. Todos los productos se someten a pruebas rigurosas de fabrica antes del envio.

Interesado en SPV-24 Outdoor Vacuum Circuit Breaker (24kV)?

Obtenga precios directos de fabrica, especificaciones tecnicas y opciones de configuracion personalizada.