Appareillage Basse Tension
SLVA Grid-Standardized Low Voltage Switchgear
SLVA grid-standardized low voltage switchgear with draw-out functional units. Three horizontal busbar ratings available: 1250A, 2000A, and 2500A, matching transformer capacities from 630 kVA to 1250 kVA. Features 8 standardized structural schemes including incoming, bus coupler, feeder, and reactive power compensation panels.
Caracteristiques Principales
- Horizontal busbar: 1250A / 2000A / 2500A
- Short-time withstand: 35–65 kA/1s
- Draw-out functional units (250A / 400A)
- 8 standardized panel configurations
- General and compact cabinet types
- SVC+SVG reactive power compensation
Specifications Techniques
| Rated Insulation Voltage | 690 V |
| System Rated Voltage | 230/400 V AC |
| Rated Frequency | 50 Hz |
| Horizontal Busbar Rated Current | 1250 / 2000 / 2500 A |
| Vertical Busbar Rated Current | 1250 / 1600 A |
| Rated Short-Time Withstand Current | 35–65 kA / 1s |
| Drawer Unit Current | 250 A / 400 A |
| Cabinet Width | 700–1000 mm (General) / 700–900 mm (Compact) |
| Overvoltage Category | IV |
| Pollution Degree | 3 |
| Grounding System | TN |
| Ambient Temperature | -5°C to +40°C |
| Altitude | ≤2000 m |
| EMC Environment | Class A |
| Installation | Indoor |
| Matching Transformer Capacity | 630 / 800 / 1000 / 1250 kVA |
Applications
Industrial and commercial power distributionMotor control centers (MCC)Reactive power compensation (SVC+SVG)Smart grid substation integration
Conformite aux Normes
IEC 61439GB 7251CCC Certified
Reponse sous 12hCertifie ISO / CE / CCCOEM Disponible
Questions Frequentes
Quelle est la tension nominale du SLVA Grid-Standardized Low Voltage Switchgear?
Le SLVA Grid-Standardized Low Voltage Switchgear a une tension nominale de varies by model. Consultez le tableau des specifications techniques pour les caracteristiques electriques completes.
Quel est le delai de livraison pour le SLVA Grid-Standardized Low Voltage Switchgear?
Le delai standard pour le SLVA Grid-Standardized Low Voltage Switchgear est d'environ 30 jours. Des quantites plus importantes ou des configurations personnalisees peuvent necessiter plus de temps.
Le SLVA Grid-Standardized Low Voltage Switchgear peut-il etre personnalise pour des projets OEM?
Oui, NAIJI Electric propose la fabrication OEM et sur mesure pour le SLVA Grid-Standardized Low Voltage Switchgear.
A quelles normes le SLVA Grid-Standardized Low Voltage Switchgear est-il conforme?
Le SLVA Grid-Standardized Low Voltage Switchgear est concu et teste conformement aux normes IEC 61439, GB 7251, CCC Certified. Tous les produits subissent des essais rigoureux avant expedition.
Interesse par le SLVA Grid-Standardized Low Voltage Switchgear?
Obtenez des prix directs usine, des specifications techniques et des options de configuration personnalisee.