38kV Outdoor Automatic Recloser
auto-recloser

38kV Outdoor Automatic Recloser

The 38kV outdoor automatic recloser serves 33kV three-phase overhead distribution lines (50/60Hz), compliant with IEC 62271-111 and IEEE C37.60. The highest voltage class in the NAIJI recloser series, completing the 15.5kV / 27kV / 38kV sequence for global 11kV, 24kV, and 33kV grid coverage. Available in three-phase ganged or independent mechanism configurations. Significantly upgraded insulation distances, creepage distances, and vacuum interrupter sizing. 304/316 stainless steel enclosure with outdoor corrosion protection.

Fitur Utama

  • 38kV rated voltage, 630A rated current
  • Power-frequency withstand: 70kV; Lightning impulse: 170kV
  • 10,000 mechanical operations life
  • Closing time: ≤60ms; Opening time: ≤45ms
  • Partial discharge: ≤20pC at 1.1Ur/√3
  • Built-in CT: 600A/1A, accuracy class 0.5S
  • Highest voltage class — completes 15.5/27/38kV series
  • Significantly upgraded insulation and creepage distances
  • 304/316 stainless steel enclosure
  • IEC 62271-111 & IEEE C37.60 compliant

Spesifikasi Teknis

Rated Voltage38kV
Rated Current630A
Power-Frequency Withstand (Phase/Earth & Across Gap)70kV
Lightning Impulse Withstand (Peak)170kV
Mechanical Life10,000 operations
Contact Gap15±1mm
Closing Time≤60ms
Opening Time≤45ms
Partial Discharge≤20pC
Built-in CT Ratio600A/1A
CT Accuracy Class0.5S (5P10)
Operating Temperature-40°C to +45°C
Frequency50/60Hz
Enclosure Material304/316 Stainless Steel
StandardsIEC 62271-111, IEEE C37.60

Aplikasi

33kV overhead distribution linesSub-transmission distribution networksDistribution automation (DA/FA)Fault isolation and auto-reclosing

Kepatuhan Standar

IEC 62271-111IEEE C37.60
Balasan dalam 12 jamBersertifikat ISO / CE / CCCOEM Tersedia

Pertanyaan yang Sering Diajukan

Berapa tegangan nominal 38kV Outdoor Automatic Recloser?
38kV Outdoor Automatic Recloser memiliki tegangan nominal 38kV. Silakan lihat tabel spesifikasi teknis untuk peringkat listrik lengkap.
Berapa waktu pengiriman untuk 38kV Outdoor Automatic Recloser?
Waktu pengiriman standar untuk 38kV Outdoor Automatic Recloser sekitar 30 hari. Jumlah lebih besar mungkin memerlukan waktu produksi tambahan.
Bisakah 38kV Outdoor Automatic Recloser dikustomisasi untuk proyek OEM?
Ya, NAIJI Electric menawarkan manufaktur OEM dan kustom untuk 38kV Outdoor Automatic Recloser.
Standar apa yang dipenuhi 38kV Outdoor Automatic Recloser?
38kV Outdoor Automatic Recloser dirancang dan diuji sesuai IEC 62271-111, IEEE C37.60. Semua produk menjalani pengujian ketat sebelum pengiriman.

Tertarik dengan 38kV Outdoor Automatic Recloser?

Dapatkan harga langsung pabrik, spesifikasi teknis dan opsi konfigurasi kustom.