38kV Outdoor Automatic Recloser
auto-recloser

38kV Outdoor Automatic Recloser

The 38kV outdoor automatic recloser serves 33kV three-phase overhead distribution lines (50/60Hz), compliant with IEC 62271-111 and IEEE C37.60. The highest voltage class in the NAIJI recloser series, completing the 15.5kV / 27kV / 38kV sequence for global 11kV, 24kV, and 33kV grid coverage. Available in three-phase ganged or independent mechanism configurations. Significantly upgraded insulation distances, creepage distances, and vacuum interrupter sizing. 304/316 stainless steel enclosure with outdoor corrosion protection.

Principais Caracteristicas

  • 38kV rated voltage, 630A rated current
  • Power-frequency withstand: 70kV; Lightning impulse: 170kV
  • 10,000 mechanical operations life
  • Closing time: ≤60ms; Opening time: ≤45ms
  • Partial discharge: ≤20pC at 1.1Ur/√3
  • Built-in CT: 600A/1A, accuracy class 0.5S
  • Highest voltage class — completes 15.5/27/38kV series
  • Significantly upgraded insulation and creepage distances
  • 304/316 stainless steel enclosure
  • IEC 62271-111 & IEEE C37.60 compliant

Especificacoes Tecnicas

Rated Voltage38kV
Rated Current630A
Power-Frequency Withstand (Phase/Earth & Across Gap)70kV
Lightning Impulse Withstand (Peak)170kV
Mechanical Life10,000 operations
Contact Gap15±1mm
Closing Time≤60ms
Opening Time≤45ms
Partial Discharge≤20pC
Built-in CT Ratio600A/1A
CT Accuracy Class0.5S (5P10)
Operating Temperature-40°C to +45°C
Frequency50/60Hz
Enclosure Material304/316 Stainless Steel
StandardsIEC 62271-111, IEEE C37.60

Aplicacoes

33kV overhead distribution linesSub-transmission distribution networksDistribution automation (DA/FA)Fault isolation and auto-reclosing

Conformidade com Normas

IEC 62271-111IEEE C37.60
Resposta em 12hCertificado ISO / CE / CCCOEM Disponivel

Perguntas Frequentes

Qual e a tensao nominal do 38kV Outdoor Automatic Recloser?
O 38kV Outdoor Automatic Recloser tem tensao nominal de 38kV. Consulte a tabela de especificacoes tecnicas para as classificacoes eletricas completas.
Qual e o prazo de entrega para o 38kV Outdoor Automatic Recloser?
O prazo padrao para o 38kV Outdoor Automatic Recloser e de aproximadamente 30 dias. Quantidades maiores podem exigir tempo adicional.
O 38kV Outdoor Automatic Recloser pode ser personalizado para projetos OEM?
Sim, a NAIJI Electric oferece fabricacao OEM e personalizada para o 38kV Outdoor Automatic Recloser.
Quais normas o 38kV Outdoor Automatic Recloser atende?
O 38kV Outdoor Automatic Recloser e projetado e testado conforme IEC 62271-111, IEEE C37.60. Todos os produtos passam por testes rigorosos antes do embarque.

Interessado no 38kV Outdoor Automatic Recloser?

Obtenha precos diretos de fabrica, especificacoes tecnicas e opcoes de configuracao personalizada.