27kV Outdoor Automatic Recloser
auto-recloser

27kV Outdoor Automatic Recloser

The 27kV outdoor automatic recloser serves 24kV three-phase overhead distribution lines (50/60Hz), compliant with IEC 62271-111 and benchmarked against IEEE C37.60. Widely adopted in South America, North America, East/South Africa, Southeast Asia, and Oceania where 24kV grids prevail. Available in three-phase ganged single-mechanism or three-phase independent mechanism configurations — independent mechanism is preferred for export projects. Upgraded insulation distances and vacuum interrupter sizing compared to the 15.5kV model. 304/316 stainless steel enclosure with outdoor powder-coat protection.

Caracteristiques Principales

  • 27kV rated voltage, 630A rated current
  • Power-frequency withstand: 70kV; Lightning impulse: 150kV
  • 10,000 mechanical operations life
  • Closing time: ≤60ms; Opening time: ≤45ms
  • Partial discharge: ≤20pC at 1.1Ur/√3
  • Built-in CT: 600A/1A, accuracy class 0.5S
  • Three-phase ganged or independent mechanism
  • Upgraded insulation for 24kV systems
  • 304/316 stainless steel enclosure
  • IEC 62271-111 & IEEE C37.60 compliant

Specifications Techniques

Rated Voltage27kV
Rated Current630A
Power-Frequency Withstand (Phase/Earth & Across Gap)70kV
Lightning Impulse Withstand (Peak)150kV
Mechanical Life10,000 operations
Contact Gap12±1mm
Closing Time≤60ms
Opening Time≤45ms
Partial Discharge≤20pC
Built-in CT Ratio600A/1A
CT Accuracy Class0.5S (5P10)
Operating Temperature-40°C to +45°C
Frequency50/60Hz
Enclosure Material304/316 Stainless Steel
StandardsIEC 62271-111, IEEE C37.60

Applications

24kV overhead distribution linesSouth America / Africa / Southeast Asia gridsDistribution automation (DA/FA)Fault isolation and auto-reclosing

Conformite aux Normes

IEC 62271-111IEEE C37.60
Reponse sous 12hCertifie ISO / CE / CCCOEM Disponible

Questions Frequentes

Quelle est la tension nominale du 27kV Outdoor Automatic Recloser?
Le 27kV Outdoor Automatic Recloser a une tension nominale de 27kV. Consultez le tableau des specifications techniques pour les caracteristiques electriques completes.
Quel est le delai de livraison pour le 27kV Outdoor Automatic Recloser?
Le delai standard pour le 27kV Outdoor Automatic Recloser est d'environ 30 jours. Des quantites plus importantes ou des configurations personnalisees peuvent necessiter plus de temps.
Le 27kV Outdoor Automatic Recloser peut-il etre personnalise pour des projets OEM?
Oui, NAIJI Electric propose la fabrication OEM et sur mesure pour le 27kV Outdoor Automatic Recloser.
A quelles normes le 27kV Outdoor Automatic Recloser est-il conforme?
Le 27kV Outdoor Automatic Recloser est concu et teste conformement aux normes IEC 62271-111, IEEE C37.60. Tous les produits subissent des essais rigoureux avant expedition.

Interesse par le 27kV Outdoor Automatic Recloser?

Obtenez des prix directs usine, des specifications techniques et des options de configuration personnalisee.