38kV Outdoor Automatic Recloser
auto-recloser

38kV Outdoor Automatic Recloser

The 38kV outdoor automatic recloser serves 33kV three-phase overhead distribution lines (50/60Hz), compliant with IEC 62271-111 and IEEE C37.60. The highest voltage class in the NAIJI recloser series, completing the 15.5kV / 27kV / 38kV sequence for global 11kV, 24kV, and 33kV grid coverage. Available in three-phase ganged or independent mechanism configurations. Significantly upgraded insulation distances, creepage distances, and vacuum interrupter sizing. 304/316 stainless steel enclosure with outdoor corrosion protection.

Caracteristiques Principales

  • 38kV rated voltage, 630A rated current
  • Power-frequency withstand: 70kV; Lightning impulse: 170kV
  • 10,000 mechanical operations life
  • Closing time: ≤60ms; Opening time: ≤45ms
  • Partial discharge: ≤20pC at 1.1Ur/√3
  • Built-in CT: 600A/1A, accuracy class 0.5S
  • Highest voltage class — completes 15.5/27/38kV series
  • Significantly upgraded insulation and creepage distances
  • 304/316 stainless steel enclosure
  • IEC 62271-111 & IEEE C37.60 compliant

Specifications Techniques

Rated Voltage38kV
Rated Current630A
Power-Frequency Withstand (Phase/Earth & Across Gap)70kV
Lightning Impulse Withstand (Peak)170kV
Mechanical Life10,000 operations
Contact Gap15±1mm
Closing Time≤60ms
Opening Time≤45ms
Partial Discharge≤20pC
Built-in CT Ratio600A/1A
CT Accuracy Class0.5S (5P10)
Operating Temperature-40°C to +45°C
Frequency50/60Hz
Enclosure Material304/316 Stainless Steel
StandardsIEC 62271-111, IEEE C37.60

Applications

33kV overhead distribution linesSub-transmission distribution networksDistribution automation (DA/FA)Fault isolation and auto-reclosing

Conformite aux Normes

IEC 62271-111IEEE C37.60
Reponse sous 12hCertifie ISO / CE / CCCOEM Disponible

Questions Frequentes

Quelle est la tension nominale du 38kV Outdoor Automatic Recloser?
Le 38kV Outdoor Automatic Recloser a une tension nominale de 38kV. Consultez le tableau des specifications techniques pour les caracteristiques electriques completes.
Quel est le delai de livraison pour le 38kV Outdoor Automatic Recloser?
Le delai standard pour le 38kV Outdoor Automatic Recloser est d'environ 30 jours. Des quantites plus importantes ou des configurations personnalisees peuvent necessiter plus de temps.
Le 38kV Outdoor Automatic Recloser peut-il etre personnalise pour des projets OEM?
Oui, NAIJI Electric propose la fabrication OEM et sur mesure pour le 38kV Outdoor Automatic Recloser.
A quelles normes le 38kV Outdoor Automatic Recloser est-il conforme?
Le 38kV Outdoor Automatic Recloser est concu et teste conformement aux normes IEC 62271-111, IEEE C37.60. Tous les produits subissent des essais rigoureux avant expedition.

Interesse par le 38kV Outdoor Automatic Recloser?

Obtenez des prix directs usine, des specifications techniques et des options de configuration personnalisee.