27kV Outdoor Automatic Recloser
auto-recloser

27kV Outdoor Automatic Recloser

The 27kV outdoor automatic recloser serves 24kV three-phase overhead distribution lines (50/60Hz), compliant with IEC 62271-111 and benchmarked against IEEE C37.60. Widely adopted in South America, North America, East/South Africa, Southeast Asia, and Oceania where 24kV grids prevail. Available in three-phase ganged single-mechanism or three-phase independent mechanism configurations — independent mechanism is preferred for export projects. Upgraded insulation distances and vacuum interrupter sizing compared to the 15.5kV model. 304/316 stainless steel enclosure with outdoor powder-coat protection.

Dac diem chinh

  • 27kV rated voltage, 630A rated current
  • Power-frequency withstand: 70kV; Lightning impulse: 150kV
  • 10,000 mechanical operations life
  • Closing time: ≤60ms; Opening time: ≤45ms
  • Partial discharge: ≤20pC at 1.1Ur/√3
  • Built-in CT: 600A/1A, accuracy class 0.5S
  • Three-phase ganged or independent mechanism
  • Upgraded insulation for 24kV systems
  • 304/316 stainless steel enclosure
  • IEC 62271-111 & IEEE C37.60 compliant

Thong so ky thuat

Rated Voltage27kV
Rated Current630A
Power-Frequency Withstand (Phase/Earth & Across Gap)70kV
Lightning Impulse Withstand (Peak)150kV
Mechanical Life10,000 operations
Contact Gap12±1mm
Closing Time≤60ms
Opening Time≤45ms
Partial Discharge≤20pC
Built-in CT Ratio600A/1A
CT Accuracy Class0.5S (5P10)
Operating Temperature-40°C to +45°C
Frequency50/60Hz
Enclosure Material304/316 Stainless Steel
StandardsIEC 62271-111, IEEE C37.60

Ung dung

24kV overhead distribution linesSouth America / Africa / Southeast Asia gridsDistribution automation (DA/FA)Fault isolation and auto-reclosing

Tuan thu tieu chuan

IEC 62271-111IEEE C37.60
Phan hoi trong 12hChung nhan ISO / CE / CCCCo san OEM

Cau hoi thuong gap

Dien ap dinh muc cua 27kV Outdoor Automatic Recloser la bao nhieu?
27kV Outdoor Automatic Recloser co dien ap dinh muc 27kV. Vui long xem bang thong so ky thuat de biet day du cac thong so dien.
Thoi gian giao hang cho 27kV Outdoor Automatic Recloser la bao lau?
Thoi gian giao hang tieu chuan cho 27kV Outdoor Automatic Recloser khoang 30 ngay. So luong lon hon co the can them thoi gian san xuat.
27kV Outdoor Automatic Recloser co the tuy chinh cho du an OEM khong?
Co, NAIJI Electric cung cap san xuat OEM va tuy chinh cho 27kV Outdoor Automatic Recloser.
27kV Outdoor Automatic Recloser tuan thu nhung tieu chuan nao?
27kV Outdoor Automatic Recloser duoc thiet ke va thu nghiem theo IEC 62271-111, IEEE C37.60. Tat ca san pham trai qua kiem tra nghiem ngat truoc khi xuat hang.

Quan tam den 27kV Outdoor Automatic Recloser?