38kV Outdoor Automatic Recloser
auto-recloser

38kV Outdoor Automatic Recloser

The 38kV outdoor automatic recloser serves 33kV three-phase overhead distribution lines (50/60Hz), compliant with IEC 62271-111 and IEEE C37.60. The highest voltage class in the NAIJI recloser series, completing the 15.5kV / 27kV / 38kV sequence for global 11kV, 24kV, and 33kV grid coverage. Available in three-phase ganged or independent mechanism configurations. Significantly upgraded insulation distances, creepage distances, and vacuum interrupter sizing. 304/316 stainless steel enclosure with outdoor corrosion protection.

Dac diem chinh

  • 38kV rated voltage, 630A rated current
  • Power-frequency withstand: 70kV; Lightning impulse: 170kV
  • 10,000 mechanical operations life
  • Closing time: ≤60ms; Opening time: ≤45ms
  • Partial discharge: ≤20pC at 1.1Ur/√3
  • Built-in CT: 600A/1A, accuracy class 0.5S
  • Highest voltage class — completes 15.5/27/38kV series
  • Significantly upgraded insulation and creepage distances
  • 304/316 stainless steel enclosure
  • IEC 62271-111 & IEEE C37.60 compliant

Thong so ky thuat

Rated Voltage38kV
Rated Current630A
Power-Frequency Withstand (Phase/Earth & Across Gap)70kV
Lightning Impulse Withstand (Peak)170kV
Mechanical Life10,000 operations
Contact Gap15±1mm
Closing Time≤60ms
Opening Time≤45ms
Partial Discharge≤20pC
Built-in CT Ratio600A/1A
CT Accuracy Class0.5S (5P10)
Operating Temperature-40°C to +45°C
Frequency50/60Hz
Enclosure Material304/316 Stainless Steel
StandardsIEC 62271-111, IEEE C37.60

Ung dung

33kV overhead distribution linesSub-transmission distribution networksDistribution automation (DA/FA)Fault isolation and auto-reclosing

Tuan thu tieu chuan

IEC 62271-111IEEE C37.60
Phan hoi trong 12hChung nhan ISO / CE / CCCCo san OEM

Cau hoi thuong gap

Dien ap dinh muc cua 38kV Outdoor Automatic Recloser la bao nhieu?
38kV Outdoor Automatic Recloser co dien ap dinh muc 38kV. Vui long xem bang thong so ky thuat de biet day du cac thong so dien.
Thoi gian giao hang cho 38kV Outdoor Automatic Recloser la bao lau?
Thoi gian giao hang tieu chuan cho 38kV Outdoor Automatic Recloser khoang 30 ngay. So luong lon hon co the can them thoi gian san xuat.
38kV Outdoor Automatic Recloser co the tuy chinh cho du an OEM khong?
Co, NAIJI Electric cung cap san xuat OEM va tuy chinh cho 38kV Outdoor Automatic Recloser.
38kV Outdoor Automatic Recloser tuan thu nhung tieu chuan nao?
38kV Outdoor Automatic Recloser duoc thiet ke va thu nghiem theo IEC 62271-111, IEEE C37.60. Tat ca san pham trai qua kiem tra nghiem ngat truoc khi xuat hang.

Quan tam den 38kV Outdoor Automatic Recloser?

Nhan gia truc tiep tu nha may, thong so ky thuat va cac tuy chon cau hinh.