SPG-12 Outdoor SF6 Load Break Switch (12kV)
SF6负荷开关

SPG-12 Outdoor SF6 Load Break Switch (12kV)

The SPG-12 is a 12kV outdoor SF6 load break switch for 10kV distribution systems. Uses SF6 pressure-assisted arc blowing in a 304 stainless steel molded housing — low gas pressure means low heat, short extinguishing time, and long life. Features low gas pressure interlock (locks operation at 0.03-0.04 MPa with visual alarm), manual interlock for safe maintenance, and high-pressure explosion-proof relief (0.4-0.6 MPa with side venting, no solid particle ejection). Silicone rubber/epoxy resin insulation with APG integral vacuum casting — 20+ years outdoor proven. Every unit X-ray inspected. Triangle spring mechanism sealed in SF6 housing — rust-free, maintenance-free. Capable of zero-gauge-pressure rated current switching. 5,000 mechanical operations life.

产品特点

  • 额定电压12kV——适用于10kV配电系统
  • SF6压气式吹弧灭弧——低热量、快速灭弧、寿命长
  • 优质304不锈钢模压壳体——年漏气率远优于国标
  • 具备零表压合分额定电流能力
  • 低气压联锁:0.03-0.04 MPa,带视觉报警指示
  • 手动联锁装置确保检修安全
  • 高压防爆泄压:0.4-0.6 MPa,侧面排气无固体颗粒飞出
  • 硅橡胶/环氧树脂绝缘(APG真空浇注)
  • 三角形弹簧机构密封于SF6壳体内——不生锈、免维护
  • 每只成品逐一X光检查
  • 机械寿命:5,000次
  • 可配FTU实现配电自动化(FA/DA)

技术参数

Rated Voltage12 kV
Rated Frequency50/60 Hz
Rated Current630 A
Rated Breaking Load Current630 A
Rated Closed Breaking Current630 A
Rated Short-Circuit Making Current (peak)50 kA
Rated Short-Time Withstand Current20 kA / 4s
Rated Cable-Charging Breaking Current10 A
Rated Earth Fault Breaking Current48 A
Lightning Impulse Withstand (phase-phase/earth)75 kV
Lightning Impulse Withstand (across isolating distance)85 kV
Power Frequency Withstand 1min (phase-phase/earth)42 kV
Power Frequency Withstand 1min (across isolating distance)48 kV
Rain Test Withstand Voltage34 kV
Rated Working Pressure0.07 MPa
Low Pressure Interlock0.03-0.04 MPa
High Pressure Explosion Relief0.4-0.6 MPa
Annual Leak Rate≤0.5%
SF6 Water Content≤150 PPM
Circuit Resistance (per phase)≤150 μΩ
Contact Distance41±3 mm
Contact Overtravel22±2 mm
Opening Speed1.9±0.2 m/s
Closing Speed1.9±0.2 m/s
Contact Closing Bounce Time≤3 ms
Phase-to-Phase Distance250±3 mm
Three-Phase Synchronization≤3 ms
Closing Time<10 s
Opening Time<10 s
Energy Storage Motor Power40 W
Mechanical Life5,000 operations
Operation VoltageDC220V / DC24V / AC220V
Weight (Manual / Automatic)115 kg / 135 kg
Temperature Range-25°C to +40°C

应用领域

Urban distribution network sectionalizingTie switch applications for 10kV systemsRural distribution system control switchingRing network fault detection, isolation, and alarmDistribution automation with FTU

执行标准

IEC 62271-103GB/T 10963
12小时内回复ISO / CE / CCC 认证支持OEM定制

常见问题

SPG-12 Outdoor SF6 Load Break Switch (12kV)的额定电压是多少?
SPG-12 Outdoor SF6 Load Break Switch (12kV)的额定电压为12 kV。完整电气参数请参阅上方技术规格表。
SPG-12 Outdoor SF6 Load Break Switch (12kV)的交货周期是多久?
SPG-12 Outdoor SF6 Load Break Switch (12kV)的标准交货周期约为30天。大批量订单或定制配置可能需要额外生产时间。请联系我们的销售团队获取准确的交货时间。
SPG-12 Outdoor SF6 Load Break Switch (12kV)可以进行OEM定制吗?
可以,耐吉电气为SPG-12 Outdoor SF6 Load Break Switch (12kV)提供OEM和定制制造服务。我们可以根据项目需求调整规格、品牌和配置。最低起订量要求适用。
SPG-12 Outdoor SF6 Load Break Switch (12kV)符合哪些标准?
SPG-12 Outdoor SF6 Load Break Switch (12kV)按照IEC 62271-103, GB/T 10963标准设计和测试。所有产品出厂前均经过严格测试。

对SPG-12 Outdoor SF6 Load Break Switch (12kV)感兴趣?

获取工厂直销价格、技术规格及定制配置方案。