15.5kV Outdoor Automatic Recloser
auto-recloser

15.5kV Outdoor Automatic Recloser

The 15.5kV outdoor automatic recloser serves 11kV three-phase AC overhead distribution lines (50/60Hz). Features solid-insulated vacuum interrupter poles with silicone-composite epoxy resin encapsulation, monostable permanent-magnet actuator with simple construction and long mechanical life. Stainless steel enclosure with outdoor powder-coat corrosion protection. IP65/IP67 rated, suitable for altitudes up to 2,000m, pollution level IV.

Key Features

  • 15.5kV rated voltage, 630A rated current
  • Power-frequency withstand: 50kV; Lightning impulse: 110kV
  • 10,000 mechanical operations life
  • Closing time: ≤60ms; Opening time: ≤45ms
  • Partial discharge: ≤20pC at 1.2Ur/√3
  • Built-in CT: 600A/1A, accuracy class 0.5S
  • Three-phase synchronization: ≤2ms
  • Contact bounce: ≤2ms
  • Operating temperature: -40°C to +45°C
  • IEC 62271-111 compliant

Technical Specifications

Rated Voltage15.5kV
Rated Current630A
Power-Frequency Withstand (Phase/Earth & Across Gap)50kV
Lightning Impulse Withstand (Peak)110kV
Mechanical Life10,000 operations
Contact Gap11±1mm
Closing Time≤60ms
Opening Time≤45ms
Partial Discharge≤20pC
Built-in CT Ratio600A/1A
CT Accuracy Class0.5S (5P10)
Operating Temperature-40°C to +45°C
Frequency50/60Hz
Protection RatingIP65/IP67
StandardIEC 62271-111

Applications

11kV overhead distribution linesRural distribution automationFault isolation and auto-reclosingSmart grid distribution networks

Standards Compliance

IEC 62271-111
Reply within 12hISO / CE / CCC CertifiedOEM Available

Frequently Asked Questions

What is the rated voltage of the 15.5kV Outdoor Automatic Recloser?
The 15.5kV Outdoor Automatic Recloser has a rated voltage of 15.5kV. Please refer to the technical specifications table above for complete electrical ratings.
What is the lead time for 15.5kV Outdoor Automatic Recloser?
Standard lead time for the 15.5kV Outdoor Automatic Recloser is approximately 30 days. Larger quantities or custom configurations may require additional production time. Contact our sales team for a precise delivery schedule.
Can the 15.5kV Outdoor Automatic Recloser be customized for OEM projects?
Yes, NAIJI Electric offers OEM and custom manufacturing for the 15.5kV Outdoor Automatic Recloser. We can adjust specifications, branding, and configurations to meet project-specific requirements. Minimum order quantities apply.
What standards does the 15.5kV Outdoor Automatic Recloser comply with?
The 15.5kV Outdoor Automatic Recloser is designed and tested in accordance with IEC 62271-111. All products undergo rigorous factory testing before shipment.