38kV Outdoor Automatic Recloser
auto-recloser

38kV Outdoor Automatic Recloser

The 38kV outdoor automatic recloser serves 33kV three-phase overhead distribution lines (50/60Hz), compliant with IEC 62271-111 and IEEE C37.60. The highest voltage class in the NAIJI recloser series, completing the 15.5kV / 27kV / 38kV sequence for global 11kV, 24kV, and 33kV grid coverage. Available in three-phase ganged or independent mechanism configurations. Significantly upgraded insulation distances, creepage distances, and vacuum interrupter sizing. 304/316 stainless steel enclosure with outdoor corrosion protection.

Key Features

  • 38kV rated voltage, 630A rated current
  • Power-frequency withstand: 70kV; Lightning impulse: 170kV
  • 10,000 mechanical operations life
  • Closing time: ≤60ms; Opening time: ≤45ms
  • Partial discharge: ≤20pC at 1.1Ur/√3
  • Built-in CT: 600A/1A, accuracy class 0.5S
  • Highest voltage class — completes 15.5/27/38kV series
  • Significantly upgraded insulation and creepage distances
  • 304/316 stainless steel enclosure
  • IEC 62271-111 & IEEE C37.60 compliant

Technical Specifications

Rated Voltage38kV
Rated Current630A
Power-Frequency Withstand (Phase/Earth & Across Gap)70kV
Lightning Impulse Withstand (Peak)170kV
Mechanical Life10,000 operations
Contact Gap15±1mm
Closing Time≤60ms
Opening Time≤45ms
Partial Discharge≤20pC
Built-in CT Ratio600A/1A
CT Accuracy Class0.5S (5P10)
Operating Temperature-40°C to +45°C
Frequency50/60Hz
Enclosure Material304/316 Stainless Steel
StandardsIEC 62271-111, IEEE C37.60

Applications

33kV overhead distribution linesSub-transmission distribution networksDistribution automation (DA/FA)Fault isolation and auto-reclosing

Standards Compliance

IEC 62271-111IEEE C37.60
Reply within 12hISO / CE / CCC CertifiedOEM Available

Frequently Asked Questions

What is the rated voltage of the 38kV Outdoor Automatic Recloser?
The 38kV Outdoor Automatic Recloser has a rated voltage of 38kV. Please refer to the technical specifications table above for complete electrical ratings.
What is the lead time for 38kV Outdoor Automatic Recloser?
Standard lead time for the 38kV Outdoor Automatic Recloser is approximately 30 days. Larger quantities or custom configurations may require additional production time. Contact our sales team for a precise delivery schedule.
Can the 38kV Outdoor Automatic Recloser be customized for OEM projects?
Yes, NAIJI Electric offers OEM and custom manufacturing for the 38kV Outdoor Automatic Recloser. We can adjust specifications, branding, and configurations to meet project-specific requirements. Minimum order quantities apply.
What standards does the 38kV Outdoor Automatic Recloser comply with?
The 38kV Outdoor Automatic Recloser is designed and tested in accordance with IEC 62271-111, IEEE C37.60. All products undergo rigorous factory testing before shipment.